ACM / MCM panels · Capital Region, NY
ACM and MCM wall panels for commercial buildings
Flat, sharp-edged aluminum composite wall panels fabricated to your shop drawings and installed by our own crew—or priced as shop fabrication only or field installation only.
Call or text (518) 888-7938
Book spring work now. Winter assessments and estimates available.
Updated November 2026

AI-generated illustration
Short answer
We fabricate and install commercial ACM and MCM wall panels across the Capital Region, working from your architectural and approved shop drawings. Panels typically use 4 mm composite sheets with PVDF finishes and either polyethylene or fire-retardant mineral cores where NFPA 285 wall assemblies apply. Choose full shop-and-field delivery, fabrication only, or field installation only. Send PDF drawings to start.
Key facts
- Service area
- Albany, Schenectady, Troy, Saratoga Springs, Clifton Park, Glens Falls and jobs within about two hours of Albany.
- Season
- Panel installation runs most of the year. Sealant joints and barrier work are done on dry, frost-free surfaces.
- Who does the work
- Our own crews, from The Dom Construction Group LLC.
- Insurance
- General liability, umbrella and workers' compensation insurance; certificates on request.
- Estimates
- Free. Start with 3–5 photos by text, or use the form.
- Reply
- We reply within one business day, Monday to Friday.
How aluminum composite panels are built
Aluminum composite material, called ACM or metal composite material (MCM), pairs two thin aluminum skins—each roughly 0.020 inches (0.5 mm) thick—bonded under heat and pressure to a solid core. On commercial building facades, 4 mm is the standard overall panel thickness, while 3 mm and 6 mm sheets are manufactured for specialized sign or high-span details. Because the two outer skins act like the flanges of a beam, an ACM panel stays flat and rigid across wide modules without the weight of heavy-gauge plate.
Sheets commonly arrive up to 60 inches wide and in long custom lengths. In the shop, we cut flat sheets on a CNC router to match the project's approved shop drawings, mill V- or U-shaped grooves through the back skin and core, and fold crisp 1- to 2-inch return legs while leaving the outer aluminum skin unbroken at the corner. Corners are closed with rivets, angles or internal clips, stiffeners are bonded to the back of larger modules, and perimeter extrusions or hanging clips are fastened to the returns.
Albany Metal Panels builds commercial metal wall panels and facades—entries, canopies, soffits, fascias, sign bands, column covers and parapet copings. We do not install metal roofs or residential house siding.
PE, FR and noncombustible cores in commercial codes
From the street, two ACM panels can look identical while carrying very different cores inside:
- Polyethylene (PE) core is standard on low-rise sign bands, canopies and smaller commercial buildings where the building code permits combustible core materials.
- Fire-retardant (FR) mineral-filled core is specified on multi-story and higher-occupancy buildings where the code and contract documents call for an NFPA 285 tested exterior wall assembly.
- Noncombustible / A2-type cores with higher mineral content are available when project specifications call for them.
The project architect and engineer of record select the core, panel thickness, backup sheathing, continuous insulation and sub-framing. We do not engineer, test or certify wall assemblies; we fabricate and install strictly to the approved shop drawings and the panel manufacturer's tested assembly specified in the contract documents.
Wet-seal route-and-return vs dry-joint ACM rainscreens
Most Capital Region ACM facades use one of two joint methods over exterior sheathing, an air and water barrier, continuous insulation and aluminum or steel girts:
- Wet-seal systems set routed-and-returned trays with roughly 1/2-inch reveals packed with backer rod and sealed with low-modulus silicone. Wet-seal panels work well on storefronts, canopies, fascia bands and renovations with tight wall depth.
- Dry-joint and open-joint rainscreen systems leave reveals open or baffled with extruded splines instead of face sealant. Any wind-driven rain passing the joint drains down a ventilated cavity behind the panels and exits at base weeps.
Where ground-level walls face carts, snowplows or heavy foot traffic, architects often pair upper-story ACM modules with thicker single-skin plate panels at the base.
PVDF coatings, panel modules and delivery options
Commercial ACM sheets come factory-finished in fluoropolymer (PVDF) and FEVE architectural coatings—solid colors, metallics, micas, anodized-look, brushed aluminum, and printed wood or stone patterns. A factory protective film stays on the panel face through shop fabrication and field installation and peels off once adjacent trades finish.
The Dom Construction Group LLC offers ACM work three ways across Albany, Schenectady, Troy, Saratoga Springs and the wider Capital Region: complete shop fabrication and field installation by our own insured crew, shop fabrication only for other installers, or field installation only when panels are furnished by others. Call or text (518) 888-7938 or use our bid request page to send drawings. We reply within one business day, Monday to Friday.
Routed folds and corner details on ACM trays

AI-generated illustration

AI-generated illustration
From shop drawings to hung ACM panels
How a commercial composite wall panel package moves through shop work and field installation.
Review plans, specs and shop drawings
We verify ACM core type, thickness, PVDF finish, sub-framing details and approved shop drawing dimensions against field conditions.
CNC route, fold and assemble trays
Flat composite sheets are routed on a CNC table, folded into crisp return legs, reinforced with corner clips and stiffeners, and labeled by elevation.
Set barriers, insulation and sub-framing
Where included in our scope, our crew installs air and water barriers, continuous insulation, thermally broken clips and plumb aluminum or steel girts.
Hang panels, seal transitions and peel film
Panels are hung to consistent reveal lines, wet-seal or perimeter silicone joints are tooled over backer rod, and factory film is peeled at turnover.
Common questions about ACM and MCM facade panels
What is the difference between ACM and MCM wall panels?
ACM stands for aluminum composite material, while MCM stands for metal composite material. On most commercial projects in the United States, the two terms refer to the same facade product: two thin aluminum face skins, each roughly 0.020 inches (0.5 mm) thick, bonded to a solid polyethylene or mineral-filled core. MCM is simply the broader industry term because composite panels can also be manufactured with zinc, copper, titanium or stainless steel skins.
When do commercial projects use FR-core ACM instead of PE-core ACM?
Polyethylene (PE) core panels are generally limited by building codes to low-rise facades, canopies and sign bands. Fire-retardant (FR) mineral-filled cores are specified where the building height, construction type or occupancy triggers requirements for an NFPA 285 tested exterior wall assembly. The project architect and engineer determine the required core, insulation and sub-framing, and our shop and field crews build strictly to the approved drawings and specified tested assembly.
How thick are standard commercial ACM facade panels?
Four millimeters (4 mm) is the standard thickness for commercial ACM exterior wall cladding, soffits, column covers and canopies, balancing light panel weight with flat stiffness across wide modules. Three-millimeter (3 mm) sheets are mainly used for flat signage and light interior trim, while 6 mm composite sheets or thicker single-skin aluminum plate panels are selected when design wind loads or impact zones demand added rigidity.
How is the factory finish on ACM panels protected during construction?
Architectural ACM sheets leave the coil-coating line with a factory-applied fluoropolymer (PVDF) or FEVE finish covered by a directional peel-off protective film. That film stays on the panel surface during CNC routing, return folding, crating, shipping and field hanging to guard against scratches and mortar or sealant smears. Installers peel the film off after panels are fastened and joint work is complete so UV exposure does not bake the adhesive onto the coating.
Can Albany Metal Panels fabricate ACM trays without installing them, or install panels bought elsewhere?
Yes. We handle ACM panel packages in three configurations depending on how the general contractor or owner is buying out the job. We can fabricate routed-and-returned panels in our shop from your approved shop drawings for another crew to hang, perform field installation only using panels supplied by others, or carry both shop fabrication and field installation under one subcontract.
Request pricing on an ACM panel package
Send architectural drawings or photos of your commercial building for a free scope review.
Other metal panel systems and scopes
- Commercial metal wall panels
Overview of ACM, single-skin plate and formed metal cladding scopes.
- Panel shop fabrication
CNC routing, return folding, stiffeners and clips built to your shop drawings.
- Field panel installation
Sub-framing girts, barriers and panel hanging by our own insured crew.
- Rainscreen panel systems
Dry-joint and open-joint ventilated cavities behind composite or plate panels.
- Aluminum plate panels
Thicker single-skin aluminum panels, column covers and parapet copings.
Pricing an ACM facade in the Capital Region?
Book spring work now. Winter assessments and estimates available.