Rainscreen cladding · Capital Region, NY

Dry-joint and open-joint metal rainscreen systems

Drained, back-ventilated ACM and aluminum plate rainscreens installed over air barriers, continuous insulation and thermally broken sub-framing.

Call or text (518) 888-7938

Book spring work now. Winter assessments and estimates available.

Updated November 2026

AI-generated illustration: a dry-joint rainscreen reveal between metal panels

AI-generated illustration

AI-generated illustration: dry-joint metal rainscreen wall system with crisp open shadow reveals.

Short answer

Dry-joint and open-joint metal rainscreen systems shed bulk wind-driven rain at the outer panel face while draining and drying any incidental moisture inside a ventilated cavity behind the cladding. We fabricate and install ACM and aluminum plate rainscreens over air barriers, continuous insulation and thermally broken sub-framing across the Capital Region. Send architectural wall sections for free pricing.

Key facts

Service area
Albany, Schenectady, Troy, Saratoga Springs, Clifton Park, Glens Falls and jobs within about two hours of Albany.
Season
Panel installation runs most of the year. Sealant joints and barrier work are done on dry, frost-free surfaces.
Who does the work
Our own crews, from The Dom Construction Group LLC.
Insurance
General liability, umbrella and workers' compensation insurance; certificates on request.
Estimates
Free. Start with 3–5 photos by text, or use the form.
Reply
We reply within one business day, Monday to Friday.

How a drained and ventilated cavity manages water

Every exterior wall sees wind-driven rain, melting snow and vapor movement. While a traditional wet-seal panel wall relies on face silicone to stop 100 percent of water at the outer joint, a drained and back-ventilated metal wall panel rainscreen separates the decorative outer skin from the primary air and weather seal behind it.

In a rainscreen assembly, the ACM or aluminum plate cladding deflects sunlight, wind and nearly all rainwater at the exterior face. The small fraction of moisture that enters a panel joint meets an open air cavity behind the panel returns, runs down the face of the continuous air and water-resistive barrier, and exits through through-wall or base weep flashings. Constant airflow from vented bottom and top reveals dries the cavity and equalizes wind pressure across the panel face, reducing the suction that pulls water through hairline gaps.

Dry-joint, open-joint and baffled panel reveals

Architects detail commercial metal rainscreens in several joint profiles depending on aesthetic goals and exposure:

  • Dry-joint spline or gasketed reveals: Extruded aluminum or composite splines sit inside perimeter panel tracks, closing the sightline into a dark, recessed shadow joint without exposed caulk that can streak or collect road dust.
  • Open-joint ventilated rainscreens: Deliberately open 3/8-inch to 1/2-inch reveals leave clean shadow lines across the facade; behind the open joint, UV-stable black-faced barriers and dark framing keep backup components invisible from the street.
  • Pressure-equalized compartments: Compartmentalized horizontal and vertical baffles divide the cavity into zones so wind gusts equalize rapidly behind the panels on taller or exposed commercial elevations.

Because there is no face sealant inside panel-to-panel reveals to crack, peel or leach plasticizer onto PVDF coatings, rainscreen facades stay cleaner over time and require less joint maintenance than wet-seal walls.

Continuous insulation and thermally broken girts

New York commercial energy codes routinely call for exterior continuous insulation outboard of steel studs or CMU backup walls. Metal rainscreens pair naturally with mineral wool insulation boards fitted tightly over a fluid-applied or sheet waterproofing air barrier.

Running continuous steel Z-girts straight through exterior insulation creates a thermal bridge that cuts effective R-value. Where specified on the architectural wall sections, our field installation crews fasten fiberglass or stainless thermally broken isolator clips to the structure and attach horizontal or vertical aluminum sub-rails outboard of the insulation, maintaining both structural wind-load transfer and thermal continuity.

Fire-retardant cores and tested wall assemblies

On multi-story commercial buildings and noncombustible wall types where building codes require an NFPA 285 tested exterior wall assembly, the design team specifies mineral-filled fire-retardant (FR) or noncombustible A2-type ACM cores along with compatible insulation, air barriers and joint details.

We do not engineer or certify wall assemblies ourselves; instead, our Albany fabrication shop and field crews build strictly to the project's approved, engineered shop drawings and the panel manufacturer's tested assembly called out in Division 07 specifications. Whether you need full fabrication and installation, panels fabricated for your own crew, or field installation only, submit drawings through our bid request page or contact form.

Rainscreen reveals and back-wall framing

AI-generated illustration: metal girts and clips over an air and water barrier, ready for panels

AI-generated illustration

AI-generated illustration: thermally broken clips, rails and continuous insulation over a weather-resistive barrier.
AI-generated illustration: a folded ACM panel corner with a riveted aluminum corner angle

AI-generated illustration

AI-generated illustration: crisp folded outside corner detail on a dry-joint composite rainscreen.
AI-generated illustration: finished metal panel facade on a commercial building

AI-generated illustration

AI-generated illustration: modern commercial elevation clad in ventilated metal rainscreen modules.

Rainscreen panel system questions

Does an open-joint rainscreen let rainwater into the building?

No, because the outer panel skin is only the rain-deflecting screen, not the primary weather seal. Behind the panels sits a continuous air and water-resistive barrier flashed at every opening and base line. Any minor wind-blown moisture entering an open or baffled reveal drains down that barrier inside the ventilated cavity and weeps out.

Why do architects choose dry-joint rainscreens over wet-seal silicone joints?

Face-sealed silicone joints require periodic inspection and eventual replacement, and aged sealants can hold airborne dirt along panel edges. Dry-joint and open-joint rainscreens eliminate face caulk between panels, maintain crisp dark shadow reveals, allow continuous cavity ventilation behind exterior insulation, and often let individual damaged panels unhook without cutting sealant.

What kind of air and water barrier belongs behind an open-joint panel wall?

Where joints are completely open rather than spline-closed, sunlight and weather reach narrow strips of the backup wall through the reveal. Specifications for open-joint rainscreens typically call for a UV-resistant, black-faced sheet membrane or UV-stable fluid-applied air barrier, paired with black-coated girts and fasteners so hardware disappears inside the shadow line.

Why are thermally broken clips used behind rainscreen panels?

Fastening continuous metal Z-girts directly through exterior mineral wool insulation conducts indoor heat straight to the cold outer cladding, sharply reducing effective wall R-value. Thermally broken clips use fiberglass, polyamide or isolated stainless brackets with thermal pads to support exterior aluminum rails while keeping the insulation layer thermally continuous.

Can damaged panels be replaced individually on a clip-and-rail rainscreen?

On many hook-on pin-and-rail rainscreen systems, individual panels lift off their slotted vertical extrusions without dismantling the entire elevation above them, provided adjacent trims or top closures allow clearance. Sequential tongue-and-groove extrusion systems lock together in order, so replacement method always depends on the exact attachment profile shown on shop drawings.

Send rainscreen wall details for a quote

Attach architectural wall sections and elevations showing your insulation, girts and panel layout.

Rather text? Text photos to (518) 888-7938

What are you seeing? (optional)
Add details (optional)
Property (optional)
How soon? (optional)
Best way to reply (optional)
Photos (optional, up to 5)

Add 3–5 photos: one close-up and one of the whole wall. We shrink them before sending.

    required. We reply within one business day, Monday to Friday. We use your details only to reply to this request. Privacy