Envelope waterproofing · Capital Region, NY

Commercial facade waterproofing, sealants and air barriers

Sheet and fluid-applied air and water barriers behind wall panels, silicone joint sealants, transition flashings and breathable wall coatings installed by our own crew.

Call or text (518) 888-7938

Book spring work now. Winter assessments and estimates available.

Updated November 2026

AI-generated illustration: a wet-seal ACM joint with backer rod and silicone sealant

AI-generated illustration

AI-generated illustration: wet-seal panel joint with backer rod and silicone sealant between folded metal returns

Short answer

Our own crews install commercial facade waterproofing across Albany and the Capital Region, either alongside our metal wall panel, EIFS and stucco packages or as a standalone scope. Work covers sheet and fluid-applied air and water barriers behind cladding, silicone sealant joints with backer rod, through-wall and perimeter flashings, and breathable elastomeric coatings. Send drawings or wall photos for pricing.

Key facts

Service area
Albany, Schenectady, Troy, Saratoga Springs, Clifton Park, Glens Falls and jobs within about two hours of Albany.
Season
Panel installation runs most of the year. Sealant joints and barrier work are done on dry, frost-free surfaces.
Who does the work
Our own crews, from The Dom Construction Group LLC.
Insurance
General liability, umbrella and workers' compensation insurance; certificates on request.
Estimates
Free. Start with 3–5 photos by text, or use the form.
Reply
We reply within one business day, Monday to Friday.

Air and water barriers behind exterior cladding

Every metal wall panel facade—especially an open-joint or dry-joint rainscreen system—depends on a continuous air and water-resistive barrier over the exterior sheathing. Panels shed most of the rain and snow, while the barrier behind the sub-framing stops air leakage and directs any moisture that enters the cavity safely back to the exterior.

Our own crews install sheet-applied membranes and fluid-applied air and water barriers before continuous insulation, thermally broken clips, Z-girts or hat channels go on the wall. Careful detailing happens before cladding ever hides the substrate: lapping flashings shingle-style, sealing rough openings at windows and louvers, striping fastener penetrations and clip bases where required by the membrane specification, and tying wall barriers cleanly into roof edges and foundation waterproofing.

Silicone panel joints and perimeter transitions

On wet-seal route-and-return ACM panels and plate panels, the joint sealant is the primary weather seal. Panel reveals—typically around 1/2 inch wide—receive closed-cell or non-gassing backer rod set to uniform depth so the silicone sealant forms an hourglass profile bonded only to the two opposing panel returns. Three-sided adhesion tears sealant apart during Upstate New York winter contraction and summer heat; proper backer-rod sizing lets the joint stretch and compress without pulling off the PVDF coating.

We also cut out and replace failed perimeter caulking where metal panels meet aluminum storefront frames, brick masonry, cast stone, EIFS or cement stucco. Dissimilar materials expand at different rates and often require primers, bond-breaker tape and non-staining silicone formulations that will not bleed plasticizers onto porous stone or metal finishes.

Through-wall flashings, copings and breathable coatings

Water rarely enters through the middle of an intact panel or plaster field; it gets in at edges, caps and unsealed transitions. Our waterproofing scope covers:

  • Sheet-metal and membrane flashings at window heads, sill pans, ledger angles, kick-outs where rooflines meet vertical walls, and shelf angles.
  • Parapet coping seals, including internal splice plates, butyl or silicone bed seals, and secondary membrane wraps beneath metal copings so wind-driven rain cannot run down the back of the facade.
  • Breathable elastomeric and masonry coatings over concrete block, precast, stucco and EIFS elevations, bridging hairline cracks while allowing trapped interior water vapor to escape rather than blistering in freeze-thaw weather.

One subcontractor for cladding and joint sealants

Splitting cladding and facade sealants between separate subcontractors often creates schedule gaps—panels sit unsealed before winter, or trades argue over whether a leak started at a window head, an air barrier lap or a panel joint. Because The Dom Construction Group LLC handles metal wall panels, EIFS, stucco, waterproofing and supported pipe scaffold with our own insured crew, general contractors and building owners can keep the weather seal under one contract.

Our field team has about 19 years of experience in EIFS, stucco, masonry and coatings, and we price both standalone commercial waterproofing packages and combined envelope scopes from your drawings or site photos. Note that our envelope work covers vertical walls, soffits, canopies and parapet copings—not roofing systems. Call or text (518) 888-7938 or submit plans on our bid request page. We reply within one business day, Monday to Friday.

Signs of facade sealant and barrier failure

Common clues on commercial walls that perimeter sealants, flashings or backup barriers are letting water in.

Split or pulled-away panel joint sealant

Gaps along the edge or center of caulked reveals between metal panels, storefronts or masonry.

Usually means
Aged urethane caulk, missing backer rod causing three-sided adhesion, or skipped primer on coated metal returns.
What we do
Cut out old sealant cleanly, set closed-cell or non-gassing backer rod to proper depth, prime where required and tool low-modulus silicone.

Staining below parapet copings and bands

Dark vertical streaks or winter icicles forming beneath metal parapet caps, sign bands or shelf angles.

Usually means
Open coping butt joints without internal splice plates or missing secondary membrane wrap under the cap.
What we do
Lift affected coping sections, install continuous membrane underlayment and sealed splice plates, and re-secure caps with proper drip clearance.

Drafts and interior leaks around window heads

Water showing at interior drywall corners after wind-driven rain, even when glass units are intact.

Usually means
Discontinuous air and water barrier laps at rough openings or missing head flashing end dams.
What we do
Open the perimeter transition, integrate flexible flashing membrane shingle-style into the wall barrier, install drip flashing and reseal.

Chalking or blistering paint on masonry or plaster

Peeling bubbles or powdery residue across coated concrete block, stucco or EIFS elevations.

Usually means
Vapor-trapping paint applied over damp walls or UV breakdown of weathered acrylic coats.
What we do
Remove loose coatings, repair substrate cracks and apply a breathable elastomeric or mineral coating formulated to pass water vapor.
AI-generated illustration: metal girts and clips over an air and water barrier, ready for panels

AI-generated illustration

AI-generated illustration: air and water barrier with continuous insulation and sub-framing behind exterior cladding

Commercial facade waterproofing questions

Why does an open-joint metal rainscreen still need a full air and water barrier?

Open-joint and dry-joint rainscreen panels intentionally skip face sealant so air pressure equalizes and trapped moisture can ventilate out of the wall cavity. Because wind-driven rain and snow mist can pass through open reveals, the sheet or fluid-applied air and water barrier over the exterior sheathing acts as the true weather plane, stopping air infiltration and guiding water down to base flashings.

Why is silicone typically used instead of urethane in wet-seal metal panel joints?

Aluminum panels expand and contract rapidly with daily sun exposure and Upstate New York winter temperature swings, placing high movement demands on 1/2-inch panel reveals. Architectural low-modulus silicone sealants stay flexible in sub-freezing cold, resist ultraviolet chalking far longer than standard urethanes, and bond reliably to fluoropolymer (PVDF) panel returns when installed over properly sized backer rod.

What causes new facade sealant joints to split down the middle or pull off one edge?

Most premature sealant failures trace back to three-sided adhesion, missing surface prep or working in wet conditions. If backer rod is omitted and sealant sticks to the back of the joint as well as both panel returns, thermal movement tears the bead. Skipping solvent wipe-downs, omitting required primers on masonry or anodized metal, or tooling joints too thin also causes early bond loss.

Do elastomeric wall coatings trap moisture inside stucco, masonry or EIFS walls?

Vapor-impermeable paints can blister and peel if interior moisture tries to migrate outward, which is why facade coatings must be matched to the wall assembly. Breathable acrylic, mineral and vapor-permeable elastomeric coatings shed wind-driven liquid rain from the exterior face while maintaining enough vapor permeance to let trace interior moisture diffuse safely without building pressure behind the finish.

Can we hire you solely for commercial caulking and air barriers without a metal panel scope?

Yes. While general contractors often combine air barriers, through-wall flashings and joint sealants with our metal wall panel, EIFS or stucco packages to keep transitions under one subcontractor, our own crews also take on standalone commercial waterproofing scopes. That includes full-building recaulking, storefront perimeter joints, parapet coping seals and fluid-applied or sheet membrane installations on new walls.

Ask for a facade waterproofing estimate

Attach elevation photos or wall section details and tell us the town and building type.

Rather text? Text photos to (518) 888-7938

What are you seeing? (optional)
Add details (optional)
Property (optional)
How soon? (optional)
Best way to reply (optional)
Photos (optional, up to 5)

Add 3–5 photos: one close-up and one of the whole wall. We shrink them before sending.

    required. We reply within one business day, Monday to Friday. We use your details only to reply to this request. Privacy

    Rather text?

    (518) 888-7938

    Call or text Monday–Friday, 7 AM–5 PM.

    Cladding and envelope work tied to waterproofing

    Need air barriers, flashing or joint sealants priced?

    Book spring work now. Winter assessments and estimates available.