ALBANY METAL PANELSFABRICATE · INSTALL · BOTH (home) Call or text (518) 888-7938 Free estimate

Metal wall panels · Capital Region, NY

Commercial metal wall panels across Albany and the Capital Region

ACM, single-skin aluminum plate and formed wall panels fabricated to approved shop drawings and installed over properly flashed commercial building envelopes.

Call or text (518) 888-7938

Book spring work now. Winter assessments and estimates available.

Updated November 2026

AI-generated illustration: finished metal panel facade on a commercial building

AI-generated illustration

AI-generated illustration: finished commercial building facade with metal wall panels and glass storefront.

Short answer

Albany Metal Panels fabricates and installs commercial metal wall panels across the Capital Region, including ACM, single-skin aluminum plate and formed wall cladding. We build wet-seal route-and-return and drained rainscreen assemblies from approved shop drawings, offering fabrication only, installation only or both. Send PDF architectural drawings or facade photos for a free estimate within one business day.

Key facts

Service area
Albany, Schenectady, Troy, Saratoga Springs, Clifton Park, Glens Falls and jobs within about two hours of Albany.
Season
Panel installation runs most of the year. Sealant joints and barrier work are done on dry, frost-free surfaces.
Who does the work
Our own crews, from The Dom Construction Group LLC.
Insurance
General liability, umbrella and workers' compensation insurance; certificates on request.
Estimates
Free. Start with 3–5 photos by text, or use the form.
Reply
We reply within one business day, Monday to Friday.

Where commercial metal wall panels fit on a building

Commercial metal wall panels give architects, developers and building owners a flat, rigid exterior skin with clean module lines and durable factory finishes. Across Albany and the Capital Region, we fabricate and install wall panels on new ground-up buildings, hospital and medical office additions, school entries, retail storefronts, auto dealerships and full facade re-clads over aging masonry or EIFS.

Typical scopes include primary exterior wall elevations, recessed or projecting entrance canopies, underside soffits, fascia sign bands, round or square column covers and roof-edge parapet copings. Every assembly we price is built for commercial building envelopes and storefront facades.

Comparing ACM, aluminum plate and formed panels

Different parts of an elevation ask for different panel materials. Most commercial projects use one or a combination of three wall panel types:

  • ACM / MCM panels: Aluminum composite material bonds two thin aluminum skins, each roughly 0.020 inch (0.5 mm) thick, to a solid core, most commonly at a 4 mm total panel thickness (with 3 mm and 6 mm options also produced). Polyethylene (PE) cores are generally limited to low-rise cladding and sign bands, while mineral-filled fire-retardant (FR) cores or noncombustible A2-type cores are specified where building codes require an NFPA 285 tested exterior wall assembly.
  • Single-skin aluminum plate: Solid aluminum sheet, commonly 0.080 to 0.125 inch thick, brake-formed into rigid pans, column wraps and heavy trims. Plate handles ground-level foot traffic and cart impact better than thin-skin composites and forms sharp custom shapes.
  • Formed metal wall panels: Roll-formed or press-formed architectural wall profiles, along with insulated metal wall panels where drawings call for a factory-foamed building envelope unit.

Building facade panels normally carry factory-applied PVDF fluoropolymer coatings in solid colors, metallics, mica, anodized-look or printed wood and stone patterns. Sheets arrive from the coil coater with a strippable protective film that stays on through shop fabrication and field hanging, then peels away once adjacent trades finish.

Wet-seal barrier walls vs drained rainscreens

How the joints between panels are built matters just as much as the face sheet. In a route-and-return wet-seal system, panels are folded into perimeter trays and set with roughly 1/2-inch joints closed by closed-cell backer rod and low-modulus silicone sealant. Wet-seal panels act as a face-sealed barrier and remain common on canopies, sign bands and straightforward low-rise storefronts.

In a dry-joint or open-joint rainscreen system, joints remain open, baffled or spline-gasketed without face caulk. Any wind-driven water passing the reveal drops into a ventilated air space over a continuous air and water barrier, draining harmlessly out the base flashing.

Scope options for general contractors and owners

We price and build strictly from architectural drawings and approved, engineered shop drawings, following the manufacturer's tested assembly specified by the project design team. Depending on how your buyout is structured, you can hire Albany Metal Panels for full shop fabrication plus field installation, shop-fabricated panels crated for your own installers, or field labor to hang owner-furnished panels.

Because our crews also self-perform waterproofing, air barriers, EIFS, stucco and supported pipe scaffolding, we handle tie-ins cleanly where metal panels meet glass, brick or plaster. General contractors can send plans on our bid request page.

Signs an existing commercial facade needs re-cladding

Common exterior problems that lead Capital Region building owners and general contractors to replace aging cladding with metal panels.

Delaminating or oil-canned sheet metal

Thin face-fastened metal fascia or spandrel panels ripple, loosen at screw heads and streak with rust.

Usually means
Light-gauge sheet pinned tightly without thermal movement clearance or rigid return folds.
What we do
Strip failed trim, inspect sheathing and install shimmed sub-framing with 4 mm ACM or heavy-gauge aluminum plate.

Repeated wet-seal joint failures

Cracked, split or debonded perimeter caulk lets wind-driven rain behind storefront bands and sign fascias.

Usually means
Sun-baked sealant installed without proper backer-rod geometry or over an unvented barrier wall.
What we do
Upgrade to a drained rainscreen over a continuous air barrier, or rebuild route-and-return joints with silicone and backer rod.

Impact-dented entry and base walls

Crushed corners, cart dents and punctured foam cladding along sidewalks, school doors and loading aprons.

Usually means
Fragile exterior finishes placed in heavy pedestrian or equipment traffic zones.
What we do
Clad ground-floor elevations and column wraps in solid 0.080 to 0.125 inch aluminum plate panels.

Chalked, patchy or mismatched additions

Multiple tenants and past remodel patches leave a retail plaza or medical office with faded, uneven exterior surfaces.

Usually means
Aged field-applied paints and mixed materials weathering at different rates.
What we do
Over-frame sound backup walls with engineered girts and factory PVDF-coated metal wall panels for a unified elevation.

Panel assemblies, joints and finished elevations

AI-generated illustration: a wet-seal ACM joint with backer rod and silicone sealant

AI-generated illustration

AI-generated illustration: route-and-return wet-seal panel joint with backer rod and silicone sealant.
AI-generated illustration: a dry-joint rainscreen reveal between metal panels

AI-generated illustration

AI-generated illustration: open-joint rainscreen panel reveal over a ventilated cavity.
AI-generated illustration: a facade mixing metal panels with EIFS and masonry

AI-generated illustration

AI-generated illustration: commercial elevation combining architectural metal panels with storefront glazing.

Commercial metal wall panel questions

When does a commercial building require FR-core ACM instead of PE-core panels?

Building codes restrict combustible exterior cladding based on construction type, building height and wall fire-resistance requirements. Polyethylene (PE) cores are generally limited to low-rise applications and signage, whereas mineral-filled fire-retardant (FR) or noncombustible A2-type cores are specified by the project architect where codes require an NFPA 285 tested exterior wall assembly.

Who engineers the panel layout, sub-framing and wind-load attachments?

Panel engineering, core selection and tested wall assembly details come from the project's architect, structural engineer or delegated-design shop drawing engineer. We do not engineer, test or certify assemblies ourselves; instead, our shop and field crews fabricate and install strictly to the project's approved shop drawings and the panel manufacturer's specified tested assembly.

How is the factory PVDF finish protected during construction?

Architectural ACM and pre-finished aluminum sheets leave the factory with a heavy strippable protective film over the PVDF fluoropolymer coating, marked with directional arrows so metallic and mica finishes stay oriented consistently. That film remains on the face through CNC routing, folding, crating and hanging, then peels away once surrounding messy trades wrap up.

Can metal wall panels go over an existing masonry or EIFS commercial facade?

Yes, provided the project's structural engineer confirms the existing backup wall can support the sub-framing and wind loads. Re-cladding typically involves stripping loose finishes, repairing wet sheathing or masonry, applying a continuous air and water barrier, fastening shimmed girts or clips back to solid structure, and hanging new wet-seal or rainscreen panels.

What causes oil-canning on metal facades and how do composite and plate systems avoid it?

Oil-canning is visible waviness in light-gauge flat sheet metal caused by coil stress, uneven sub-framing or thermal movement pinned by face fasteners. Four-millimeter ACM panels resist waviness through their bonded sandwich core, while 0.080 to 0.125 inch aluminum plate relies on thicker metal, folded returns, rear stiffeners and shimmed sub-framing that lets panels expand freely.

Request pricing for metal wall cladding

Send architectural elevations, Division 07 specs or photos of an existing commercial building.

Rather text? Text photos to (518) 888-7938

What are you seeing? (optional)
Add details (optional)
Property (optional)
How soon? (optional)
Best way to reply (optional)
Photos (optional, up to 5)

Add 3–5 photos: one close-up and one of the whole wall. We shrink them before sending.

    required. We reply within one business day, Monday to Friday. We use your details only to reply to this request. Privacy

    Rather text?

    (518) 888-7938

    Call or text Monday–Friday, 7 AM–5 PM.

    Specific panel services and systems

    Have architectural elevations ready to price?

    Book spring work now. Winter assessments and estimates available.